On Fri, Apr 18, 2008 at 06:40:12PM -0700, Martin Hess wrote:
> I had to do 3 things to get this working:
>
> 1) Set BIOS ConsoleRedirection Terminal Type to VT100
> 2) Set my terminal emulator to VT100
> 3) Set my terminal window size to 80x24
>
> This worked for my SuperMicro board.
>
> On Apr
I had to do 3 things to get this working:
1) Set BIOS ConsoleRedirection Terminal Type to VT100
2) Set my terminal emulator to VT100
3) Set my terminal window size to 80x24
This worked for my SuperMicro board.
On Apr 18, 2008, at 4:28 PM, Hebenstreit, Michael wrote:
I've been using Ipmitool SO
I've been using Ipmitool SOL for remote control of a linux cluster (RH4
based). Everything works fine, except that BIOS screen is completely
garbled and almost unusable. Any recommendations which terminals to use
as a front end - and what settings on both the forwarding and receiving
end.
Thanks f