Robert Metzger created FLINK-17769: -------------------------------------- Summary: Wrong order of log events on a task failure Key: FLINK-17769 URL: https://issues.apache.org/jira/browse/FLINK-17769 Project: Flink Issue Type: Bug Components: Runtime / Task Reporter: Robert Metzger Fix For: 1.11.0
In this example, errors from the {{close()}} method call are logged before the {{switched from RUNNING to FAILED}} log line with the actual exception (which is confusing, because the exceptions coming from {{close()}} could be considered as the failure root cause, because they are first in the log) {code} 2020-05-14 10:12:42,660 INFO org.apache.flink.streaming.connectors.kinesis.FlinkKinesisProducer [] - Started Kinesis producer instance for region 'eu-central-1' 2020-05-14 10:12:42,660 DEBUG org.apache.flink.streaming.api.operators.BackendRestorerProcedure [] - Creating operator state backend for StreamSource_cbc357ccb763df2852fee8c4fc7d55f2_(1/1) with empty state. 2020-05-14 10:12:42,823 INFO org.apache.flink.streaming.connectors.kinesis.FlinkKinesisProducer [] - Closing producer 2020-05-14 10:12:42,823 INFO org.apache.flink.streaming.connectors.kinesis.FlinkKinesisProducer [] - Flushing outstanding 2 records 2020-05-14 10:12:42,826 ERROR org.apache.flink.streaming.runtime.tasks.StreamTask [] - Error during disposal of stream operator. org.apache.flink.kinesis.shaded.com.amazonaws.services.kinesis.producer.DaemonException: The child process has been shutdown and can no longer accept messages. 2020-05-14 10:12:42,834 WARN org.apache.flink.runtime.taskmanager.Task [] - Source: Custom Source -> Sink: Unnamed (1/1) (4a49aea047aeb3e67cf79c788df0e558) switched from RUNNING to FAILED. {code} -- This message was sent by Atlassian Jira (v8.3.4#803005)