https://issues.apache.org/jira/browse/FLINK-14107?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Thomas Weise resolved FLINK-14107.
----------------------------------
    Fix Version/s: 1.10.0
       Resolution: Fixed

> Kinesis consumer record emitter deadlock under event time alignment
> -------------------------------------------------------------------
>
>                 Key: FLINK-14107
>                 URL: https://issues.apache.org/jira/browse/FLINK-14107
>             Project: Flink
>          Issue Type: Bug
>          Components: Connectors / Kinesis
>    Affects Versions: 1.8.2, 1.9.0
>            Reporter: Thomas Weise
>            Assignee: Thomas Weise
>            Priority: Major
>              Labels: pull-request-available
>             Fix For: 1.10.0
>
>          Time Spent: 40m
>  Remaining Estimate: 0h
>
> When the emitter reaches the max timestamp for the current queue, it stops 
> emitting and waits for the max timestamp to advance. Since it simultaneously 
> selects the next queue as the new "minimum" queue, it may deadlock if the 
> previous min queue represents the new global lower bound after the max 
> timestamp advanced. This occurs very infrequently and we were finally able to 
> reproduce.



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to