https://issues.apache.org/jira/browse/IGNITE-4901?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Nikolay Tikhonov updated IGNITE-4901:
-------------------------------------
    Priority: Trivial  (was: Major)

> Decrease logging level for DataStremer retry 
> ---------------------------------------------
>
>                 Key: IGNITE-4901
>                 URL: https://issues.apache.org/jira/browse/IGNITE-4901
>             Project: Ignite
>          Issue Type: Improvement
>          Components: cache
>    Affects Versions: 1.9
>            Reporter: Nikolay Tikhonov
>            Priority: Trivial
>
> When topology are changed DataStreame log the following error message which 
> confused users. Need to decrease logging level for this case.
> {noformat}
> ERROR  Failed to execute compound future reducer: GridCompoundFuture [...] 
> class org.apache.ignite.IgniteCheckedException: DataStreamer request failed 
> [node=9d405934-eb78-4452-a3a8-fc44c3c61e76] 
>       at 
> org.apache.ignite.internal.processors.datastreamer.DataStreamerImpl$Buffer.onResponse(DataStreamerImpl.java:1777)
>  
>       at 
> org.apache.ignite.internal.processors.datastreamer.DataStreamerImpl$3.onMessage(DataStreamerImpl.java:335)
>  
>       at 
> org.apache.ignite.internal.managers.communication.GridIoManager.invokeListener(GridIoManager.java:1080)
>  
>       at 
> org.apache.ignite.internal.managers.communication.GridIoManager.processRegularMessage0(GridIoManager.java:708)
>  
>       at 
> org.apache.ignite.internal.managers.communication.GridIoManager.access$1700(GridIoManager.java:101)
>  
>       at 
> org.apache.ignite.internal.managers.communication.GridIoManager$5.run(GridIoManager.java:671)
>  
>       at 
> java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1142)
>  
>       at 
> java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:617)
>  
>       at java.lang.Thread.run(Thread.java:745) 
> Caused by: class org.apache.ignite.IgniteCheckedException: DataStreamer will 
> retry data transfer at stable topology [...] 
>       at 
> org.apache.ignite.internal.processors.datastreamer.DataStreamProcessor.localUpdate(DataStreamProcessor.java:337)
>  
>       at 
> org.apache.ignite.internal.processors.datastreamer.DataStreamProcessor.processRequest(DataStreamProcessor.java:297)
>  
>       at 
> org.apache.ignite.internal.processors.datastreamer.DataStreamProcessor.access$000(DataStreamProcessor.java:56)
>  
>       at 
> org.apache.ignite.internal.processors.datastreamer.DataStreamProcessor$1.onMessage(DataStreamProcessor.java:86)
>  
>       ... 7 more 
> {noformat}



--
This message was sent by Atlassian JIRA
(v6.3.15#6346)

Reply via email to