On Wed, Feb 13, 2019 at 11:08:16AM +, Giovanni Bellac via juniper-nsp wrote:
> after powering off a QFX5100-48T (request system power-off) the fans are
> spinning down and the ALARM LED is lightning red. The switch is working and
> looking as expected without any error messages.
>
> Is this
On Mi, Feb 13, 2019 at 11:08:16 +, Giovanni Bellac via juniper-nsp
wrote:
>
> after powering off a QFX5100-48T (request system power-off) the fans
> are spinning down and the ALARM LED is lightning red. The switch is
> working and looking as expected without any error messages.
>
> Is this
Hi all,
short update:We experiencing the red alarm only when the management port is
connected when powering off the QFX5100-48T - weird...When the management port
is not connected when powering down the device, there is no red alarm.
Kind regardsOguzhan
Am Mittwoch, 13. Februar 2019, 12:08:
Hi all,
after powering off a QFX5100-48T (request system power-off) the fans are
spinning down and the ALARM LED is lightning red. The switch is working and
looking as expected without any error messages.
Is this a normal behavior ? Has someone a spare unit for a short test ?
Thanks and kind r