Re: [j-nsp] Does QinQ work with VPLS on Juniper300?

2021-02-08 Thread Benny Lyne Amorsen
Roger Wiklund writes: > That's interesting. According to this page QinQ is not supported on > SRX300/320, not sure if that has anything to do with it? Just a little comment in case someone else needs QinQ on small SRXs: Layer 3 termination of QinQ does work on SRX, even if VPLS does not. That

Re: [j-nsp] Does QinQ work with VPLS on Juniper300?

2021-02-01 Thread Try Chhay
Dear Roger, Many thanks for advising and sharing the link as the reference. Kind regards, Try Chhay On Tue, Feb 2, 2021 at 3:09 AM Roger Wiklund wrote: > That's interesting. According to this page QinQ is not supported on > SRX300/320, not sure if that has anything to do with it? > >

Re: [j-nsp] Does QinQ work with VPLS on Juniper300?

2021-02-01 Thread Roger Wiklund
That's interesting. According to this page QinQ is not supported on SRX300/320, not sure if that has anything to do with it? Configuring Q-in-Q Tunneling on Security Devices - TechLibrary - Juniper Networks

[j-nsp] Does QinQ work with VPLS on Juniper300?

2021-01-27 Thread Try Chhay
Dear Juniper NSP, We are trying to get QinQ working with VPLS on Juniper SRX300 but the configuration of QinQ seems limited with VPLS as we cannot insert full QinQ commands. a. Below is my QinQ Configuration is working fine on Juniper SRX300 without having any VPLS set interfaces ge-0/0/0