When the circuit is up, try and rapid ping end to end - is the ping
continuously okay ?
if it keeps stopping at regular intervals perhaps you have clock slip.
If the clocksource is good, I don't understand why you see this issue.
Did you open a jtac case ?
cheers
Sean
On 4/17/09 10:02 AM,
On Friday 17 April 2009 04:22:48 pm Sean Clarke wrote:
If the clocksource is good, I don't understand why you
see this issue.
Just for kicks, does the link come back up only when you
physically reset the link?
How about resetting the interface via software? Does that
re-establish the link?
I may be missing the point, but I thought a DDF was just where you wired
up the E1's too ..
Is there any active box in between the 2 x routers, providing clock ?
Have you tried with BOTH ENDS set to internal clocking ?
cheers
Sean
On 4/17/09 10:02 AM, Faizal Rachman wrote:
Both interface
3 matches