See https://kb.juniper.net/InfoCenter/index?page=content&id=KB26889 (requires
a Juniper login). You could be hitting a PR, or the card is physically
damaged.
Also try restarting the CB:
* To ‘reset a Control Board’, for example on an MX480:
* Run the CLI command ‘request chassis cb slot # offline
No it's an older card, but I can't find firmware requirements anywhere.
Johan
On Thu, Jul 2, 2020 at 3:13 PM Jared Mauch wrote:
> Is this a newer one? I’ve seen vendors release revised boards that have
> the same part number but require newer software.
>
> - Jared
>
> > On Jul 2, 2020, at 8:19
Is this a newer one? I’ve seen vendors release revised boards that have the
same part number but require newer software.
- Jared
> On Jul 2, 2020, at 8:19 AM, john doe wrote:
>
> Hi
>
> I just started up an SCBE we had on the shelf, has anyone seen this error
> before?
>
> Major CB 0 SG2P R
Hi
I just started up an SCBE we had on the shelf, has anyone seen this error
before?
Major CB 0 SG2P Revision unsupported
CB 0 REV 20 750-031391Enhanced MX SCB
Isn't the firmware usually bundled with software upgrades? Is there a
way to upgrade the SCBE?
Johan