That's the SFP vendor that I had issues with too.
I remember there's a fix on of the the recent release notes for the same vendor
but for its XFF and SFP+ xceivers. Probably there's a chance of logging in a
case with Juniper for 1GE SFPs.
ihsan
On Jun 22, 2012, at 8:41 PM, Gustavo Santos wrote
Thanks for your answer.
All of a sudden the log message stop to show on "show log messages".
The module is the one below.
PIC port information:
FiberXcvr vendor
Port Cable typetype Xcvr vendorpart number
Wavelength
2 GIGE
I've had those messages too when I plugged in the SFPs. Some SFP brands that
used to work on GE PICs and MICs on M/T/MX series on 10.4 now complains of the
same error logs.
I can't recall the specific EEPROM ID offhand but maybe you can jog my memory
by running show chassis pic on the slot.
On
Hi,
We just bough some SFP-LX and we're getting these log messages below.
Jun 20 11:18:53.863 2012 BRD01 tfeb0 PQ3_IIC(WR): no target ack on byte 0
(wait spins 3)
Jun 20 11:18:53.864 2012 BRD01 tfeb0 PQ3_IIC(WR): I/O error
(i2c_stat=0xa3, i2c_ctl[1]=0xb0, bus_addr=0x51)
Jun 20 11:18:53.884 2012
4 matches