Re: [j-nsp] anyone running VC with 2 * EX4500?

2012-02-24 Thread Alexander Bochmann
Hi, ...on Wed, Feb 22, 2012 at 11:06:55AM +0100, Tore Anderson wrote: > * Alexander Bochmann > > we've been putting off converting our EX4500s to a virtual > > chassis for quite some time now. I've seen a few posts about > > mixed EX4500/4200 setups, but none with several EX4500s. > Works

Re: [j-nsp] anyone running VC with 2 * EX4500?

2012-02-22 Thread Tore Anderson
* Alexander Bochmann > we've been putting off converting our EX4500s to a virtual > chassis for quite some time now. I've seen a few posts about > mixed EX4500/4200 setups, but none with several EX4500s. > > Does anyone run something like that? Any special caveats, > and should we wait some m

Re: [j-nsp] anyone running VC with 2 * EX4500?

2012-02-21 Thread Ben Dale
Hi Alex, On 21/02/2012, at 8:38 PM, Alexander Bochmann wrote: > we've been putting off converting our EX4500s to a virtual > chassis for quite some time now. I've seen a few posts about > mixed EX4500/4200 setups, but none with several EX4500s. > > Does anyone run something like that? Any spe

Re: [j-nsp] anyone running VC with 2 * EX4500?

2012-02-21 Thread Phil Bedard
I did some lab testing with a 2xEX4500 VC using 10GE interfaces and it worked fairly well once everything was setup. For some reason I had some issues getting things to correctly come up but after rebooting a couple times everything was fine, even across reboots. I only tested basic L2 and L3 fun

Re: [j-nsp] anyone running VC with 2 * EX4500?

2012-02-21 Thread Doug Hanks
Just make sure you're running the right version of code. I think EX4500-VC is supported as of 11.1 or 11.2. You'll also need the VC modules in back. Thank you, -- Doug Hanks - JNCIE-ENT #213, JNCIE-SP #875 Sr. Systems Engineer Juniper Networks On 2/21/12 2:38 AM, "Alexander Bochmann" wrote

[j-nsp] anyone running VC with 2 * EX4500?

2012-02-21 Thread Alexander Bochmann
Hi, we've been putting off converting our EX4500s to a virtual chassis for quite some time now. I've seen a few posts about mixed EX4500/4200 setups, but none with several EX4500s. Does anyone run something like that? Any special caveats, and should we wait some more before trying it? Thank