[frameworks-krunner] [Bug 433549] DBus Interface Definition Appears to be Wrong

2021-02-27 Thread Ben Aaron Goldberg
https://bugs.kde.org/show_bug.cgi?id=433549 --- Comment #7 from Ben Aaron Goldberg --- (In reply to Alexander Lohnau from comment #6) > Where do you have the XML file from? > > Could you please try it with a copy from master: > https://invent.kde.org/frameworks/krunner/-/blob/mas

[frameworks-krunner] [Bug 433549] DBus Interface Definition Appears to be Wrong

2021-02-24 Thread Ben Aaron Goldberg
https://bugs.kde.org/show_bug.cgi?id=433549 --- Comment #2 from Ben Aaron Goldberg --- Yes. I'm writing my plugin in Rust using the dbus Rust library. Originally when I was writing my code I use returning a 32-bit unsigned int and knrunner wouldn't show my matches. I then noticed that the python

[frameworks-krunner] [Bug 433549] DBus Interface Definition Appears to be Wrong

2021-02-24 Thread Ben Aaron Goldberg
https://bugs.kde.org/show_bug.cgi?id=433549 --- Comment #5 from Ben Aaron Goldberg --- I'm not a cpp dev but looking at the code for krunner it appears that the value in question is a Plasma::QueryMatch::Type which is a cpp enum. I believe cpp enums are represented as "int"s with

[frameworks-krunner] [Bug 433549] DBus Interface Definition Appears to be Wrong

2021-02-24 Thread Ben Aaron Goldberg
https://bugs.kde.org/show_bug.cgi?id=433549 Ben Aaron Goldberg changed: What|Removed |Added Ever confirmed|1 |0 Status|CONFIRMED