https://bugs.kde.org/show_bug.cgi?id=407332

            Bug ID: 407332
           Summary: Wrong position of krunner window in a Plasma session
                    (Wayland)
           Product: krunner
           Version: unspecified
          Platform: Kubuntu Packages
                OS: Linux
            Status: REPORTED
          Severity: normal
          Priority: NOR
         Component: general
          Assignee: k...@privat.broulik.de
          Reporter: alexey-il...@ya.ru
  Target Milestone: ---

Created attachment 119913
  --> https://bugs.kde.org/attachment.cgi?id=119913&action=edit
Observed result

When you start a Plasma session using Wayland, the KRunner input window is
displayed at the top edge of the screen, regardless of whether or not the
Plasma panel or Latte Dock panel is at the same edge.

STEPS TO REPRODUCE
1. Start Plasma Wayland session.
2. Move or create new Plasma panel (Latte Dock panel) at top of the desktop.
3. Call KRunner window (by pressing Alt+F2, etc.)

OBSERVED RESULT
Wrong position of KRunner input window. A window appears from the edge of the
screen.

EXPECTED RESULT
Right position of KRunner input window. A window appears from the edge of an
existing panel.

SOFTWARE/OS VERSIONS
Linux: 5.0.0
KDE Plasma Version: 5.15
KDE Frameworks Version: 5.57
Qt Version: 5.12.2
Latte Dock Version: 0.8.8

-- 