https://bugs.kde.org/show_bug.cgi?id=425582
Bug ID: 425582 Summary: Use separate scales for values of different units Product: ksysguard Version: 5.19.4 Platform: Other OS: Linux Status: REPORTED Severity: normal Priority: NOR Component: Plasmoid / Applet Assignee: ksysguard-b...@kde.org Reporter: devuran...@gmx.net CC: plasma-b...@kde.org Target Milestone: --- OBSERVED RESULT I would like to plot CPU temperature in °C and CPU clock frequency in MHz in the same graph. Since both use the same scale, the clock frequency (>1000) dominates the temperature (<100) and the resulting graph does no longer have high enough resolution to be useful. EXPECTED RESULT Using separate scales and min/max values for sources of different units (°C and MHz) would alleviate my problem. SOFTWARE/OS VERSIONS Operating System: Gentoo Linux KDE Plasma Version: 5.19.4 KDE Frameworks Version: 5.73.0 Qt Version: 5.15.0 Kernel Version: 5.8.1 OS Type: 64-bit Processors: 8 × AMD Ryzen 5 2400G with Radeon Vega Graphics Memory: 13,5 GiB of RAM Graphics Processor: AMD RAVEN -- You are receiving this mail because: You are watching all bug changes.