[plasma-systemmonitor] [Bug 445297] Sensor system monitor prints NVMe drive temperature of ~50°C in text but draws graph at absolute zero / 0K / -273°C

2021-11-24 Thread Arjen Hiemstra
https://bugs.kde.org/show_bug.cgi?id=445297 Arjen Hiemstra changed: What|Removed |Added Status|REPORTED|RESOLVED Resolution|---

[plasma-systemmonitor] [Bug 445297] Sensor system monitor prints NVMe drive temperature of ~50°C in text but draws graph at absolute zero / 0K / -273°C

2021-11-24 Thread Dennis Schridde
https://bugs.kde.org/show_bug.cgi?id=445297 --- Comment #5 from Dennis Schridde --- Created attachment 143898 --> https://bugs.kde.org/attachment.cgi?id=143898=edit screenshot of NVMe drive temperature sensor settings screen I disabled the checkbox at "Automatic Y Data Range" in the "Data

[plasma-systemmonitor] [Bug 445297] Sensor system monitor prints NVMe drive temperature of ~50°C in text but draws graph at absolute zero / 0K / -273°C

2021-11-23 Thread Nate Graham
https://bugs.kde.org/show_bug.cgi?id=445297 Nate Graham changed: What|Removed |Added CC||n...@kde.org -- You are receiving this mail

[plasma-systemmonitor] [Bug 445297] Sensor system monitor prints NVMe drive temperature of ~50°C in text but draws graph at absolute zero / 0K / -273°C

2021-11-20 Thread Dennis Schridde
https://bugs.kde.org/show_bug.cgi?id=445297 --- Comment #4 from Dennis Schridde --- (In reply to Dennis Schridde from comment #3) > nvme-pci-0900 > Adapter: PCI adapter > Composite:+44.9°C (low = -273.1°C, high = +83.8°C) >(crit = +83.8°C) > Sensor 1: +44.9°C

[plasma-systemmonitor] [Bug 445297] Sensor system monitor prints NVMe drive temperature of ~50°C in text but draws graph at absolute zero / 0K / -273°C

2021-11-18 Thread Dennis Schridde
https://bugs.kde.org/show_bug.cgi?id=445297 --- Comment #3 from Dennis Schridde --- (In reply to Arjen Hiemstra from comment #2) > One interesting thing here is that there's two separate decimal separators > in the screenshot, so there seems to be something weird going on, one > possibility is

[plasma-systemmonitor] [Bug 445297] Sensor system monitor prints NVMe drive temperature of ~50°C in text but draws graph at absolute zero / 0K / -273°C

2021-11-18 Thread Arjen Hiemstra
https://bugs.kde.org/show_bug.cgi?id=445297 --- Comment #2 from Arjen Hiemstra --- One interesting thing here is that there's two separate decimal separators in the screenshot, so there seems to be something weird going on, one possibility is that something fails to convert from string to

[plasma-systemmonitor] [Bug 445297] Sensor system monitor prints NVMe drive temperature of ~50°C in text but draws graph at absolute zero / 0K / -273°C

2021-11-10 Thread Dennis Schridde
https://bugs.kde.org/show_bug.cgi?id=445297 --- Comment #1 from Dennis Schridde --- P.S. I will need some instructions on what information you will need to debug this. -- You are receiving this mail because: You are watching all bug changes.