sonic3021 writes: > I'm looking for a solution so that kea doesn't send the renew-timter and > rebind-timers. > I comment the parameter in config json file but the server also send thease > options in default value > I find some printer can't process the dhcp packet contain the option 58 and > 59 > is someone have solution already ???
=> it is a funny problem because the code only add these options when timers have a value in the subnet configuration, and this is an impossible condition because timers have default global values which are inherited by subnets where they are not specified... Unfortunately I am afraid the only solution is to attach a piece of code on the pkt4_send hook point which simply removes these options (bool delOption(uint16_t type); which is a Pkt method is your friend) from the response4 parameter... Should take between 10 and 20 lines. Thanks Francis Dupont <fdup...@isc.org> _______________________________________________ Kea-users mailing list Kea-users@lists.isc.org https://lists.isc.org/mailman/listinfo/kea-users