Re: [Lcms-user] Converting Lab to Lab values for different illuminants

2013-11-15 Thread Martin Florek
I forget the adaptation state at first, now it works (first absolute colorimetric, then relative colorimetric), thank you. For high temperatures I get a warm tint and for low temperatures I get a cold tint in my colors. Looks good. Thank you again. Regards, Martin On 15.11.2013 13:48, marti

Re: [Lcms-user] Converting Lab to Lab values for different illuminants

2013-11-15 Thread marti . maria
> The Lab-2-Lab conversion with different illuminants is just first > step in my conversion. Then I apply an ICC profile and convert to > RGB with the relative colorimetric intent. Is possible to create a > multi-profile transform with different intents for each > transformation? I do not

Re: [Lcms-user] Converting Lab to Lab values for different illuminants

2013-11-15 Thread Martin Florek
Hello Marti, Thank you for the quick reply. The Lab-2-Lab conversion with different illuminants is just first step in my conversion. Then I apply an ICC profile and convert to RGB with the relative colorimetric intent. Is possible to create a multi-profile transform with different intents for e

Re: [Lcms-user] Converting Lab to Lab values for different illuminants

2013-11-15 Thread marti . maria
Quoting Martin Florek : > Hello, > I would like to convert a D50 Lab values to Lab values for a different > color temperature illuminant. Is this possible with Little CMS, and if > then how? Tahnk you. Hi Martin, Yes, it is certainly possible. - Create A D50 Lab profile by using cmsCreateLab

[Lcms-user] Converting Lab to Lab values for different illuminants

2013-11-14 Thread Martin Florek
Hello, I would like to convert a D50 Lab values to Lab values for a different color temperature illuminant. Is this possible with Little CMS, and if then how? Tahnk you. Martin -- DreamFactory - Open Source REST & JSON