On Mon, May 11, 2020 at 01:02:19PM +0200, Sebastian Reichel wrote:
> From: Samu Nuutamo
>
> When tsi-as-adc is configured it is possible for in7[0123]_input read to
> return an incorrect value if a concurrent read to in[456]_input is
> performed. This is caused by a concurrent manipulation of the
Hi Guenter,
On Mon, May 11, 2020 at 09:51:25AM -0700, Guenter Roeck wrote:
> On 5/11/20 4:02 AM, Sebastian Reichel wrote:
> > From: Samu Nuutamo
> >
> > When tsi-as-adc is configured it is possible for in7[0123]_input read to
> > return an incorrect value if a concurrent read to in[456]_input is
On 5/11/20 4:02 AM, Sebastian Reichel wrote:
> From: Samu Nuutamo
>
> When tsi-as-adc is configured it is possible for in7[0123]_input read to
> return an incorrect value if a concurrent read to in[456]_input is
> performed. This is caused by a concurrent manipulation of the mux
> channel without
From: Samu Nuutamo
When tsi-as-adc is configured it is possible for in7[0123]_input read to
return an incorrect value if a concurrent read to in[456]_input is
performed. This is caused by a concurrent manipulation of the mux
channel without proper locking as hwmon and mfd use different locks for
4 matches