On Mon, 18 Feb 2019 07:03:10 +
Mike Looijmans wrote:
> On 16-02-19 12:27, Himanshu Jha wrote:
> > Hello Mike,
> >
> > On Fri, Feb 15, 2019 at 02:47:55PM +0100, Mike Looijmans wrote:
> >> The SPI interface implementation was completely broken.
> >
> > My apologies!
> >
> > SPI interface
..
> > Report temperature in millidegrees Celcius instead of degrees.
>
> Jonathan, I didn't know about this but is there any rationale to report
> in millidegress ?
Misguided attempt in the early days of IIO to match hwmon units.
Sadly it is now the ABI and hence 'unfixable'. Same odd units
f
On 16-02-19 12:27, Himanshu Jha wrote:
> Hello Mike,
>
> On Fri, Feb 15, 2019 at 02:47:55PM +0100, Mike Looijmans wrote:
>> The SPI interface implementation was completely broken.
>
> My apologies!
>
> SPI interface caused me a lot of trouble in my project timeline. I tried
> many different ways
Hello Mike,
On Fri, Feb 15, 2019 at 02:47:55PM +0100, Mike Looijmans wrote:
> The SPI interface implementation was completely broken.
My apologies!
SPI interface caused me a lot of trouble in my project timeline. I tried
many different ways to try playing with acpi dsl, printks etc. One
of the p
The SPI interface implementation was completely broken.
When using the SPI interface, there are only 7 address bits, the upper bit
is controlled by a page select register. The core needs access to both
ranges, so implement register read/write for both regions. The regmap
paging functionality didn'