On 21/10/16 17:43, Gwendal Grignou wrote:
> On Fri, Oct 21, 2016 at 1:17 AM, Enric Balletbo i Serra
> wrote:
>> According the ACPI specification (Version 5.0 Errata A) [1], the data
>> coming from the sensor represent the ambient light illuminance reading
>> expressed in lux. Unfortunately ACPI in
On Fri, Oct 21, 2016 at 1:17 AM, Enric Balletbo i Serra
wrote:
> According the ACPI specification (Version 5.0 Errata A) [1], the data
> coming from the sensor represent the ambient light illuminance reading
> expressed in lux. Unfortunately ACPI interface doesn't provide a
> mechanism to calibrat
According the ACPI specification (Version 5.0 Errata A) [1], the data
coming from the sensor represent the ambient light illuminance reading
expressed in lux. Unfortunately ACPI interface doesn't provide a
mechanism to calibrate this value, so this raw value can be slightly
wrong.
This patch adds
3 matches