Hi Dave,
Thanks for your review
On Fri, Dec 18, 2020 at 02:45:54PM +, Dave Stevenson wrote:
> On Fri, 18 Dec 2020 at 14:21, Dave Stevenson
> wrote:
> >
> > Hi Maxime & Dom
> >
> > On Thu, 10 Dec 2020 at 13:47, Maxime Ripard wrote:
> > >
> > > From: Dom Cobley
> > >
> > > Currently we call
On Fri, 18 Dec 2020 at 14:21, Dave Stevenson
wrote:
>
> Hi Maxime & Dom
>
> On Thu, 10 Dec 2020 at 13:47, Maxime Ripard wrote:
> >
> > From: Dom Cobley
> >
> > Currently we call cec_phys_addr_invalidate on a hotplug deassert.
> > That may be due to a TV power cycling, or an AVR being switched
>
Hi Maxime & Dom
On Thu, 10 Dec 2020 at 13:47, Maxime Ripard wrote:
>
> From: Dom Cobley
>
> Currently we call cec_phys_addr_invalidate on a hotplug deassert.
> That may be due to a TV power cycling, or an AVR being switched
> on (and switching edid).
>
> This makes CEC unusable since our contro
From: Dom Cobley
Currently we call cec_phys_addr_invalidate on a hotplug deassert.
That may be due to a TV power cycling, or an AVR being switched
on (and switching edid).
This makes CEC unusable since our controller wouldn't have a physical
address anymore.
Set it back up again on the hotplug
4 matches