From: Steffen Dirkwinkel <s.dirkwin...@beckhoff.com>

There are several Beckhoff Automation industrial PC boards which use
pmc_plt_clk* clocks for ethernet controllers. This adds affected boards
to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and
not turned off.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Steffen Dirkwinkel <s.dirkwin...@beckhoff.com>
---
 drivers/platform/x86/pmc_atom.c | 24 ++++++++++++++++++++++++
 1 file changed, 24 insertions(+)

diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index a311f48ce7c9..b1d804376237 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -413,6 +413,30 @@ static const struct dmi_system_id critclk_systems[] = {
                        DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
                },
        },
+       {
+               /* pmc_plt_clk* - are used for ethernet controllers */
+               .ident = "Beckhoff CB3163",
+               .matches = {
+                       DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
+                       DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
+               },
+       },
+       {
+               /* pmc_plt_clk* - are used for ethernet controllers */
+               .ident = "Beckhoff CB6263",
+               .matches = {
+                       DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
+                       DMI_MATCH(DMI_BOARD_NAME, "CB6263"),
+               },
+       },
+       {
+               /* pmc_plt_clk* - are used for ethernet controllers */
+               .ident = "Beckhoff CB6363",
+               .matches = {
+                       DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
+                       DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
+               },
+       },
        { /*sentinel*/ }
 };
 
-- 
2.21.0

Reply via email to