On Sat, 01 Dec 2018, Jonathan Cameron wrote:
> On Wed, 28 Nov 2018 09:14:32 +
> Lee Jones wrote:
>
> > On Mon, 19 Nov 2018, Vignesh R wrote:
> >
> > > When performing single ended measurements with TSCADC, its recommended
> > > to set negative input (SEL_INM_SWC_3_0) of ADC step to ADC's VR
On Wed, 28 Nov 2018 09:14:32 +
Lee Jones wrote:
> On Mon, 19 Nov 2018, Vignesh R wrote:
>
> > When performing single ended measurements with TSCADC, its recommended
> > to set negative input (SEL_INM_SWC_3_0) of ADC step to ADC's VREFN in the
> > corresponding STEP_CONFIGx register.
> > Also
On Mon, 19 Nov 2018, Vignesh R wrote:
> When performing single ended measurements with TSCADC, its recommended
> to set negative input (SEL_INM_SWC_3_0) of ADC step to ADC's VREFN in the
> corresponding STEP_CONFIGx register.
> Also, the positive(SEL_RFP_SWC_2_0) and negative(SEL_RFM_SWC_1_0)
> re
On Mon, 19 Nov 2018 12:12:36 +0530
Vignesh R wrote:
> When performing single ended measurements with TSCADC, its recommended
> to set negative input (SEL_INM_SWC_3_0) of ADC step to ADC's VREFN in the
> corresponding STEP_CONFIGx register.
> Also, the positive(SEL_RFP_SWC_2_0) and negative(SEL_RF
When performing single ended measurements with TSCADC, its recommended
to set negative input (SEL_INM_SWC_3_0) of ADC step to ADC's VREFN in the
corresponding STEP_CONFIGx register.
Also, the positive(SEL_RFP_SWC_2_0) and negative(SEL_RFM_SWC_1_0)
reference voltage for ADC step needs to be set to V