From: Peter Geis <pgwipe...@gmail.com>

[ Upstream commit f4eccc7fea203cfb35205891eced1ab51836f362 ]

Current implementation defaults the hda clocks to clk_m. This causes hda
to run too slow to operate correctly. Fix this by defaulting to pll_p and
setting the frequency to the correct rate.

This matches upstream t124 and downstream t30.

Acked-by: Jon Hunter <jonath...@nvidia.com>
Tested-by: Ion Agorria <i...@agorria.com>
Acked-by: Sameer Pujar <spu...@nvidia.com>
Acked-by: Thierry Reding <tred...@nvidia.com>
Signed-off-by: Peter Geis <pgwipe...@gmail.com>
Link: https://lore.kernel.org/r/20210108135913.2421585-2-pgwipe...@gmail.com
Signed-off-by: Takashi Iwai <ti...@suse.de>
Signed-off-by: Sasha Levin <sas...@kernel.org>
---
 drivers/clk/tegra/clk-tegra30.c | 2 ++
 1 file changed, 2 insertions(+)

diff --git a/drivers/clk/tegra/clk-tegra30.c b/drivers/clk/tegra/clk-tegra30.c
index 7b4c6a488527d..501929d9f70ed 100644
--- a/drivers/clk/tegra/clk-tegra30.c
+++ b/drivers/clk/tegra/clk-tegra30.c
@@ -1263,6 +1263,8 @@ static struct tegra_clk_init_table init_table[] 
__initdata = {
        { TEGRA30_CLK_I2S3_SYNC, TEGRA30_CLK_CLK_MAX, 24000000, 0 },
        { TEGRA30_CLK_I2S4_SYNC, TEGRA30_CLK_CLK_MAX, 24000000, 0 },
        { TEGRA30_CLK_VIMCLK_SYNC, TEGRA30_CLK_CLK_MAX, 24000000, 0 },
+       { TEGRA30_CLK_HDA, TEGRA30_CLK_PLL_P, 102000000, 0 },
+       { TEGRA30_CLK_HDA2CODEC_2X, TEGRA30_CLK_PLL_P, 48000000, 0 },
        /* must be the last entry */
        { TEGRA30_CLK_CLK_MAX, TEGRA30_CLK_CLK_MAX, 0, 0 },
 };
-- 
2.27.0