It takes some significant time between when we ask the EC to enable the
DCON power and when we can access the DCON registers.

FIXME: Maybe some of the delay is caused on the DCON side once the power
is good. Need to check with a scope I suppose.

Signed-off-by: Lubomir Rintel <lkund...@v3.sk>
---
 drivers/platform/olpc/olpc-ec.c | 11 ++++++-----
 1 file changed, 6 insertions(+), 5 deletions(-)

diff --git a/drivers/platform/olpc/olpc-ec.c b/drivers/platform/olpc/olpc-ec.c
index f64b82824db28..faecb73bd8430 100644
--- a/drivers/platform/olpc/olpc-ec.c
+++ b/drivers/platform/olpc/olpc-ec.c
@@ -394,11 +394,12 @@ static struct regulator_ops dcon_regulator_ops = {
 };
 
 static const struct regulator_desc dcon_desc = {
-       .name   = "dcon",
-       .id     = 0,
-       .ops    = &dcon_regulator_ops,
-       .type   = REGULATOR_VOLTAGE,
-       .owner  = THIS_MODULE,
+       .name           = "dcon",
+       .id             = 0,
+       .ops            = &dcon_regulator_ops,
+       .type           = REGULATOR_VOLTAGE,
+       .owner          = THIS_MODULE,
+       .enable_time    = 25000,
 };
 
 static int olpc_ec_probe(struct platform_device *pdev)
-- 
2.28.0