Quoting Peng Fan (2019-05-19 19:03:19)
> To Frac pll, the gate shift is 13, however to Int PLL the gate shift
> is 11.
>
> Cc:
> Fixes: ba5625c3e27 ("clk: imx: Add clock driver support for imx8mm")
> Signed-off-by: Peng Fan
> Reviewed-by: Fabio Estevam
> Reviewed-by: Jacky Bai
> ---
Applied t
To Frac pll, the gate shift is 13, however to Int PLL the gate shift
is 11.
Cc:
Fixes: ba5625c3e27 ("clk: imx: Add clock driver support for imx8mm")
Signed-off-by: Peng Fan
Reviewed-by: Fabio Estevam
Reviewed-by: Jacky Bai
---
V3:
Move Fixes Tag to correct place
V2:
Update commit with Fixes