On 20.11.2015 18:22, Jacob Siverskog wrote:
This is according to figure 12 ("I2C Programming Procedure") in
"Si5351A/B/C Data Sheet"
(https://www.silabs.com/Support%20Documents/TechnicalDocs/Si5351-B.pdf).
Without the PLL soft reset, we were unable to get three outputs
working at the same time.
This is according to figure 12 ("I2C Programming Procedure") in
"Si5351A/B/C Data Sheet"
(https://www.silabs.com/Support%20Documents/TechnicalDocs/Si5351-B.pdf).
Without the PLL soft reset, we were unable to get three outputs
working at the same time.
According to Silicon Labs support, performing
Hi!
A representative from SiLabs writes: "All the currently published versions
of the Si5351 (v1.0) and AN619 (v0.6) do not include the “Si5351A/C only”
disclaimer. Based on this and our current understanding, I see no issue
performing a PLLB reset for ‘B’ type devices.". Hence, it should not be
an
3 matches