On 12.04.19 09:48, Daniel Drake wrote:
> On Thu, Apr 11, 2019 at 1:44 PM Yurii Pavlovskyi
> wrote:
>> Event codes are expected to be polled from a queue on at least some
>> models.
>
> Maybe avoid the word "poll" since it suggests something else (at least to me).
Ok, will change this in the
On Thu, Apr 11, 2019 at 1:44 PM Yurii Pavlovskyi
wrote:
> Event codes are expected to be polled from a queue on at least some
> models.
Maybe avoid the word "poll" since it suggests something else (at least to me).
> The fix flushes the old key codes out of the queue on load and after
>
Event codes are expected to be polled from a queue on at least some
models.
The WMI event codes are pushed into queue based on circular buffer. After
INIT method is called ACPI code is allowed to push events into this buffer
the INIT method can not be reverted. If the module is unloaded and an
3 matches