These bindings can be used to register Maxim ModelGauge ICs fuel gauge
(MAX17040/41/43/44/48/49/58/59)

Signed-off-by: Vladimir Barinov <vladimir.bari...@cogentembedded.com>

---
 Documentation/devicetree/bindings/power_supply/modelgauge_battery.txt |   61 
++++++++++
 1 file changed, 61 insertions(+)

Index: 
battery-2.6/Documentation/devicetree/bindings/power_supply/modelgauge_battery.txt
===================================================================
--- /dev/null   1970-01-01 00:00:00.000000000 +0000
+++ 
battery-2.6/Documentation/devicetree/bindings/power_supply/modelgauge_battery.txt
   2014-02-02 01:36:12.638624341 +0400
@@ -0,0 +1,61 @@
+modelgauge_battery
+~~~~~~~~~~~~~~~~~~
+
+Required properties:
+ - compatible          : should contain one of the following:
+                         - "maxim,max17040" for MAX17040
+                         - "maxim,max17041" for MAX17041
+                         - "maxim,max17043" for MAX17043
+                         - "maxim,max17044" for MAX17044
+                         - "maxim,max17048" for MAX17048
+                         - "maxim,max17049" for MAX17049
+                         - "maxim,max17058" for MAX17058
+                         - "maxim,max17059" for MAX17059
+
+Optional properties:
+ - maxim,rcomp0                        : ModelGauge RCOMP parameter, used for
+                                 temperature compensation (u8);
+ - maxim,temp-co-up            : ModelGauge TempCoUp parameter, used for
+                                 temperature compensation (signed);
+ - maxim,temp-co-down          : ModelGauge TempCoDown parameter, used for
+                                 temperature compensation (signed);
+ - maxim,ocvtest               : ModelGauge OCVTest parameter, used for
+                                 verification of Custom Model calibration data
+                                 loaded into IC RAM (u16);
+ - maxim,soc-check-a           : ModelGauge SOCCheckA parameter, used for
+                                 verification of Custom Model calibration data
+                                 loaded into IC RAM (u8);
+ - maxim,soc-check-b           : ModelGauge SOCCheckB parameter, used for
+                                 verification of Custom Model calibration data
+                                 loaded into IC RAM (u8);
+ - maxim,bits                  : ModelGauge Bits parameter, used as
+                                 scaling parameter in Custom Model algorithm 
(u8);
+ - maxim,model-data            : ModelGauge ModelData data,
+                                 Custom Model calibration data (array_u8[64]).
+
+Example:
+
+modelgauge@36 {
+       compatible = "maxim,max17058";
+       reg = <0x36>;
+       interrupt-parent = <&msmgpio>;
+       interrupts = <107 0x2>;
+
+       maxim,rcomp0 = /bits/ 8 <175>;
+       maxim,temp-co-up = <(-1100)>;
+       maxim,temp-co-down = <(-4000)>;
+       maxim,ocvtest = /bits/ 16 <56144>;
+       maxim,soc-check-a = /bits/ 8 <241>;
+       maxim,soc-check-b = /bits/ 8 <243>;
+       maxim,bits = /bits/ 8 <19>;
+
+       maxim,model-data = /bits/ 8 <
+               0x9B 0x70 0xAB 0x30 0xB5 0xA0 0xB9 0xD0
+               0xBB 0xA0 0xBC 0x00 0xBC 0xB0 0xBD 0x00
+               0xBD 0x60 0xBE 0x40 0xBF 0x40 0xC1 0xF0
+               0xC5 0x60 0xC8 0xA0 0xCD 0x00 0xD1 0x50
+               0x00 0xE0 0x01 0x80 0x18 0x60 0x1C 0x20
+               0x54 0x00 0x6A 0xC0 0x79 0x20 0x65 0xC0
+               0x0B 0xE0 0x2A 0xC0 0x1D 0x00 0x17 0xE0
+               0x15 0xE0 0x11 0xE0 0x11 0x00 0x11 0x00>;
+};
--