Re: [PATCH v3 02/14] media: mt9m111: prevent module removal while in use

2016-08-14 Thread Robert Jarzmik
Hans Verkuil writes: > On 08/08/2016 09:30 PM, Robert Jarzmik wrote: >> The mt9m111 can be a removable module : the only case where the module >> should be kept loaded is while it is used, ie. while an active >> transation is ongoing on it. >> >> The notion of active

Re: [PATCH v3 02/14] media: mt9m111: prevent module removal while in use

2016-08-14 Thread Robert Jarzmik
Hans Verkuil writes: > On 08/08/2016 09:30 PM, Robert Jarzmik wrote: >> The mt9m111 can be a removable module : the only case where the module >> should be kept loaded is while it is used, ie. while an active >> transation is ongoing on it. >> >> The notion of active transaction is mapped on

Re: [PATCH v3 02/14] media: mt9m111: prevent module removal while in use

2016-08-14 Thread Hans Verkuil
On 08/08/2016 09:30 PM, Robert Jarzmik wrote: > The mt9m111 can be a removable module : the only case where the module > should be kept loaded is while it is used, ie. while an active > transation is ongoing on it. > > The notion of active transaction is mapped on the power state of the > module

Re: [PATCH v3 02/14] media: mt9m111: prevent module removal while in use

2016-08-14 Thread Hans Verkuil
On 08/08/2016 09:30 PM, Robert Jarzmik wrote: > The mt9m111 can be a removable module : the only case where the module > should be kept loaded is while it is used, ie. while an active > transation is ongoing on it. > > The notion of active transaction is mapped on the power state of the > module

[PATCH v3 02/14] media: mt9m111: prevent module removal while in use

2016-08-08 Thread Robert Jarzmik
The mt9m111 can be a removable module : the only case where the module should be kept loaded is while it is used, ie. while an active transation is ongoing on it. The notion of active transaction is mapped on the power state of the module : if powered on the removal is prohibited. Signed-off-by:

[PATCH v3 02/14] media: mt9m111: prevent module removal while in use

2016-08-08 Thread Robert Jarzmik
The mt9m111 can be a removable module : the only case where the module should be kept loaded is while it is used, ie. while an active transation is ongoing on it. The notion of active transaction is mapped on the power state of the module : if powered on the removal is prohibited. Signed-off-by: