On Tue, Jun 18, 2019 at 12:28:02PM +, Bharat Kumar Gogada wrote:
[...]
> > Applied to pci/xilinx for v5.3, please have a look and check if the commit
> > log
> > I wrote provides a clear description of the issue.
> >
> > Lorenzo
> Thanks Lorenzo and Marc.
> Lorenzo, can you please point to
>
> On Wed, Jun 12, 2019 at 03:47:59PM +0530, Bharat Kumar Gogada wrote:
> > The current Multi MSI data programming fails if multiple end points
> > requesting MSI and multi MSI are connected with switch, i.e the
> > current multi MSI data being given is not considering the number of
> > vectors b
On Wed, Jun 12, 2019 at 03:47:59PM +0530, Bharat Kumar Gogada wrote:
> The current Multi MSI data programming fails if multiple end points
> requesting MSI and multi MSI are connected with switch, i.e the current
> multi MSI data being given is not considering the number of vectors
> being requeste
On Wed, Jun 12, 2019 at 02:01:56PM +0100, Marc Zyngier wrote:
> On Wed, 12 Jun 2019 11:17:59 +0100,
> Bharat Kumar Gogada wrote:
> >
> > The current Multi MSI data programming fails if multiple end points
> > requesting MSI and multi MSI are connected with switch, i.e the current
> > multi MSI da
On Wed, 12 Jun 2019 11:17:59 +0100,
Bharat Kumar Gogada wrote:
>
> The current Multi MSI data programming fails if multiple end points
> requesting MSI and multi MSI are connected with switch, i.e the current
> multi MSI data being given is not considering the number of vectors
> being requested
The current Multi MSI data programming fails if multiple end points
requesting MSI and multi MSI are connected with switch, i.e the current
multi MSI data being given is not considering the number of vectors
being requested in case of multi MSI.
Ex: Two EP's connected via switch, EP1 requesting sin