On Sun, May 05, 2024 at 08:52:06PM +0200, Karel Balej wrote:
> Should I then drop this op and the max_uA values from all the
> regulators?
Probably, yes.
signature.asc
Description: PGP signature
Mark Brown, 2024-05-06T00:15:01+09:00:
> On Sat, May 04, 2024 at 09:37:06PM +0200, Karel Balej wrote:
>
> > +static const struct regulator_ops pm886_ldo_ops = {
> > + .list_voltage = regulator_list_voltage_table,
> > + .map_voltage = regulator_map_voltage_iterate,
> > + .set_voltage_sel =
On Sat, May 04, 2024 at 09:37:06PM +0200, Karel Balej wrote:
> +static const struct regulator_ops pm886_ldo_ops = {
> + .list_voltage = regulator_list_voltage_table,
> + .map_voltage = regulator_map_voltage_iterate,
> + .set_voltage_sel = regulator_set_voltage_sel_regmap,
> +
Support the LDO and buck regulators of the Marvell 88PM886 PMIC.
Signed-off-by: Karel Balej
---
Notes:
v6:
- Remove all definitions (now present in the header).
v5:
- Add remaining regulators.
- Clean up includes.
- Address Mark's feedback:
- Use dedicated regmap