On Fri, Mar 03, 2017 at 10:20:44PM +0100, Harald Geyer wrote:
> I don't know whether the binding document or the implementation is wrong,
> so can't propose a fix for this. Sorry.
The documentation for the fixed and GPIO regulators needs to be updated,
it the property is optional for general regu
Hi!
Documentation/devicetree/bindings/regulator/regulator.txt says that the
regulator-name property is optional. However fixed and gpio regulators
fail in probe with the following message, if the property is not
present:
| reg-fixed-voltage regulators:sensor_supply: Failed to allocate supply
2 matches