Re: [PATCH 3/3] usb: cdns3: Enable workaround for USB2.0 PHY Rx compliance test PHY lockup

2020-08-27 Thread Felipe Balbi
Hi, Roger Quadros writes: > From: Pawel Laszczak > > USB2.0 PHY hangs in Rx Compliance test when the incoming packet > amplitude is varied below and above the Squelch Level of Receiver > during the active packet multiple times. > > Version

Re: [PATCH 3/3] usb: cdns3: Enable workaround for USB2.0 PHY Rx compliance test PHY lockup

2020-08-27 Thread Peter Chen
On 20-08-25 15:00:59, Roger Quadros wrote: > From: Pawel Laszczak > > USB2.0 PHY hangs in Rx Compliance test when the incoming packet > amplitude is varied below and above the Squelch Level of > Receiver during the active packet multiple times. > > Version 1 of the controller allows PHY to be re

Re: [PATCH 3/3] usb: cdns3: Enable workaround for USB2.0 PHY Rx compliance test PHY lockup

2020-08-27 Thread Roger Quadros
On 27/08/2020 03:24, Peter Chen wrote: On 20-08-26 15:49:57, Roger Quadros wrote: Peter, On 26/08/2020 11:07, Peter Chen wrote: On 20-08-26 04:04:01, Pawel Laszczak wrote: On 20-08-25 15:00:59, Roger Quadros wrote: From: Pawel Laszczak USB2.0 PHY hangs in Rx Compliance test when the

Re: [PATCH 3/3] usb: cdns3: Enable workaround for USB2.0 PHY Rx compliance test PHY lockup

2020-08-26 Thread Peter Chen
On 20-08-26 15:49:57, Roger Quadros wrote: > Peter, > > On 26/08/2020 11:07, Peter Chen wrote: > > > > > > > > > > > > > > On 20-08-26 04:04:01, Pawel Laszczak wrote: > > > > > > On 20-08-25 15:00:59, Roger Quadros wrote: > > > > > > > From: Pawel Laszczak > > > > > > > > > > > > > > USB2.0 P

Re: [PATCH 3/3] usb: cdns3: Enable workaround for USB2.0 PHY Rx compliance test PHY lockup

2020-08-26 Thread Roger Quadros
Peter, On 26/08/2020 11:07, Peter Chen wrote: On 20-08-26 04:04:01, Pawel Laszczak wrote: On 20-08-25 15:00:59, Roger Quadros wrote: From: Pawel Laszczak USB2.0 PHY hangs in Rx Compliance test when the incoming packet amplitude is varied below and above the Squelch Level of Receiver d

RE: [PATCH 3/3] usb: cdns3: Enable workaround for USB2.0 PHY Rx compliance test PHY lockup

2020-08-26 Thread Peter Chen
> > > > > >On 20-08-26 04:04:01, Pawel Laszczak wrote: > >> >On 20-08-25 15:00:59, Roger Quadros wrote: > >> >> From: Pawel Laszczak > >> >> > >> >> USB2.0 PHY hangs in Rx Compliance test when the incoming packet > >> >> amplitude is varied below and above the Squelch Level of Receiver > >> >>

RE: [PATCH 3/3] usb: cdns3: Enable workaround for USB2.0 PHY Rx compliance test PHY lockup

2020-08-26 Thread Pawel Laszczak
> >On 20-08-26 04:04:01, Pawel Laszczak wrote: >> >On 20-08-25 15:00:59, Roger Quadros wrote: >> >> From: Pawel Laszczak >> >> >> >> USB2.0 PHY hangs in Rx Compliance test when the incoming packet >> >> amplitude is varied below and above the Squelch Level of >> >> Receiver during the active pac

Re: [PATCH 3/3] usb: cdns3: Enable workaround for USB2.0 PHY Rx compliance test PHY lockup

2020-08-26 Thread Peter Chen
On 20-08-26 04:04:01, Pawel Laszczak wrote: > >On 20-08-25 15:00:59, Roger Quadros wrote: > >> From: Pawel Laszczak > >> > >> USB2.0 PHY hangs in Rx Compliance test when the incoming packet > >> amplitude is varied below and above the Squelch Level of > >> Receiver during the active packet multipl

RE: [PATCH 3/3] usb: cdns3: Enable workaround for USB2.0 PHY Rx compliance test PHY lockup

2020-08-25 Thread Pawel Laszczak
>On 20-08-25 15:00:59, Roger Quadros wrote: >> From: Pawel Laszczak >> >> USB2.0 PHY hangs in Rx Compliance test when the incoming packet >> amplitude is varied below and above the Squelch Level of >> Receiver during the active packet multiple times. >> >> Version 1 of the controller allows PHY to

Re: [PATCH 3/3] usb: cdns3: Enable workaround for USB2.0 PHY Rx compliance test PHY lockup

2020-08-25 Thread Peter Chen
On 20-08-25 15:00:59, Roger Quadros wrote: > From: Pawel Laszczak > > USB2.0 PHY hangs in Rx Compliance test when the incoming packet > amplitude is varied below and above the Squelch Level of > Receiver during the active packet multiple times. > > Version 1 of the controller allows PHY to be re