Re: [PATCH V4 2/2] thermal: generic-adc: Add ADC based thermal sensor driver

2016-04-20 Thread Eduardo Valentin
On Thu, Apr 21, 2016 at 06:42:16AM +0530, Laxman Dewangan wrote: > > On Thursday 21 April 2016 05:13 AM, Eduardo Valentin wrote: > >Laxman, > > > >On Tue, Apr 19, 2016 at 12:52:01PM +0530, Laxman Dewangan wrote: > >>In some of platform, thermal sensors like NCT thermistors are > >>connected to the

Re: [PATCH V4 2/2] thermal: generic-adc: Add ADC based thermal sensor driver

2016-04-20 Thread Laxman Dewangan
On Thursday 21 April 2016 05:13 AM, Eduardo Valentin wrote: Laxman, On Tue, Apr 19, 2016 at 12:52:01PM +0530, Laxman Dewangan wrote: In some of platform, thermal sensors like NCT thermistors are connected to the one of ADC channel. The temperature is read by reading the voltage across the sens

Re: [PATCH V4 2/2] thermal: generic-adc: Add ADC based thermal sensor driver

2016-04-20 Thread Eduardo Valentin
Laxman, On Tue, Apr 19, 2016 at 12:52:01PM +0530, Laxman Dewangan wrote: > In some of platform, thermal sensors like NCT thermistors are > connected to the one of ADC channel. The temperature is read by > reading the voltage across the sensor resistance via ADC. Lookup > table for ADC read value t

Re: [PATCH V4 2/2] thermal: generic-adc: Add ADC based thermal sensor driver

2016-04-19 Thread Jonathan Cameron
On 19/04/16 08:22, Laxman Dewangan wrote: > In some of platform, thermal sensors like NCT thermistors are > connected to the one of ADC channel. The temperature is read by > reading the voltage across the sensor resistance via ADC. Lookup > table for ADC read value to temperature is referred to get