On 03/21/2014 04:21 AM, Stanislav Meduna wrote:
On 21.03.2014 02:39, Peter Hurley wrote:
Does disabling the fifo on shutdown clear the fifo?
I did not try this, but if my theory is correct, it would
not help, as all this does is reducing the FIFO length
to one character. So you'd still get up
On 21.03.2014 02:39, Peter Hurley wrote:
> Does disabling the fifo on shutdown clear the fifo?
I did not try this, but if my theory is correct, it would
not help, as all this does is reducing the FIFO length
to one character. So you'd still get up to two characters:
one in the "FIFO" - it could g
On 03/14/2014 04:11 PM, Stanislav Meduna wrote:
Hi,
following scenario:
- a Freescale i.MX28 machine
- RS232 AUART looped back Rx - Tx or two different ports cross-connected
- a test program sending data in one thread and receiving in the other:
thread A periodically sends "Quick brown fox j
Hi,
following scenario:
- a Freescale i.MX28 machine
- RS232 AUART looped back Rx - Tx or two different ports cross-connected
- a test program sending data in one thread and receiving in the other:
thread A periodically sends "Quick brown fox jumps over the lazy dog",
thread B receives