Re: [PATCH 1/8] pm80xx: configure PHY settings based on subsystem vendor ID

2015-11-02 Thread Jack Wang
Reviewed-by: Jack Wang Thanks Jack 2015-10-30 15:53 GMT+01:00 Benjamin Rood : > Previuosly, all PMC Sierra 80xx controllers are assumed to be a > motherboard controller, except if the subsystem vendor ID was equal to > PCI_VENDOR_ID_ADAPTEC. The driver then attempts to load PHY settings > from

Re: [PATCH 1/8] pm80xx: configure PHY settings based on subsystem vendor ID

2015-11-01 Thread Hannes Reinecke
On 10/30/2015 03:53 PM, Benjamin Rood wrote: > Previuosly, all PMC Sierra 80xx controllers are assumed to be a > motherboard controller, except if the subsystem vendor ID was equal to > PCI_VENDOR_ID_ADAPTEC. The driver then attempts to load PHY settings > from NVRAM. While this may be correct be

[PATCH 1/8] pm80xx: configure PHY settings based on subsystem vendor ID

2015-10-30 Thread Benjamin Rood
Previuosly, all PMC Sierra 80xx controllers are assumed to be a motherboard controller, except if the subsystem vendor ID was equal to PCI_VENDOR_ID_ADAPTEC. The driver then attempts to load PHY settings from NVRAM. While this may be correct behavior for most controllers, it does not work with Ad