Hey Tim,
On 04-05-17 05:51, Tim Kryger wrote:
On Wed, May 3, 2017 at 8:40 AM, Olliver Schinagl wrote:
Hey Tim,
Ok, so as far as I understand (from the datasheet) the intended way to do
this would be to check for the BUSY IRQ & USR[0] IRQ and if it is busy,
(re-write) the LCR. We no longer
Hey Tim,
On 03-05-17 16:22, Tim Kryger wrote:
On Wed, May 3, 2017 at 4:26 AM, Olliver Schinagl wrote:
Hey Chen-Yu
On 03-05-17 12:40, Chen-Yu Tsai wrote:
On Wed, May 3, 2017 at 6:17 PM, Olliver Schinagl
wrote:
Hey Jamie,
Several years ago you wrote the glue-code [0] for the DW 8250 IP. O
Hey Chen-Yu
On 03-05-17 12:40, Chen-Yu Tsai wrote:
On Wed, May 3, 2017 at 6:17 PM, Olliver Schinagl wrote:
Hey Jamie,
Several years ago you wrote the glue-code [0] for the DW 8250 IP. Over the
years various 'fixes' have been applied to resolve certain 'weird' problems
that Tim tried to fix wi
On Wed, May 3, 2017 at 6:17 PM, Olliver Schinagl wrote:
> Hey Jamie,
>
> Several years ago you wrote the glue-code [0] for the DW 8250 IP. Over the
> years various 'fixes' have been applied to resolve certain 'weird' problems
> that Tim tried to fix with [1].
>
> After going over the datasheets an
Hey Jamie,
Several years ago you wrote the glue-code [0] for the DW 8250 IP. Over
the years various 'fixes' have been applied to resolve certain 'weird'
problems that Tim tried to fix with [1].
After going over the datasheets and code with a comb several times now,
I think I may have found o