On 23.08.2018 13:09, Ajay Singh wrote:
> On Thu, 23 Aug 2018 11:11:09 +0300
> Claudiu Beznea wrote:
>
>> On 14.08.2018 09:50, Ajay Singh wrote:
>>> Avoid use of static variable and move it in 'wilc' structure
>>> related to hif and added NULL before accessing hif_workqueue in
>>> wilc_enqueue_
On Thu, 23 Aug 2018 11:11:09 +0300
Claudiu Beznea wrote:
> On 14.08.2018 09:50, Ajay Singh wrote:
> > Avoid use of static variable and move it in 'wilc' structure
> > related to hif and added NULL before accessing hif_workqueue in
> > wilc_enqueue_work().
> >
> > Below variables are moved to 'wi
On 14.08.2018 09:50, Ajay Singh wrote:
> Avoid use of static variable and move it in 'wilc' structure related to
> hif and added NULL before accessing hif_workqueue in wilc_enqueue_work().
>
> Below variables are moved to 'wilc' struct:
> struct workqueue_struct *hif_workqueue;
> struct mutex
Avoid use of static variable and move it in 'wilc' structure related to
hif and added NULL before accessing hif_workqueue in wilc_enqueue_work().
Below variables are moved to 'wilc' struct:
struct workqueue_struct *hif_workqueue;
struct mutex hif_deinit_lock;
struct completion hif_driver_comp;