On P1022DS both ethernet controllers are connected to RGMII PHYs accessible via MDIO bus. Remove fixed-link property from ethernet nodes as they only required when fixed link PHYs without MDIO bus are used. Signed-off-by: Felix Radensky fe...@embedded-sol.com ---

Re: [PATCH] powerpc/p1022ds: Remove fixed-link property from ethernet nodes.

2011-07-07 Thread Timur Tabi
Felix Radensky wrote: On P1022DS both ethernet controllers are connected to RGMII PHYs accessible via MDIO bus. Remove fixed-link property from ethernet nodes as they only required when fixed link PHYs without MDIO bus are used. Signed-off-by: Felix Radensky fe...@embedded-sol.com

Re: [PATCH] powerpc/p1022ds: Remove fixed-link property from ethernet nodes.

2011-07-07 Thread Kumar Gala
On Jul 7, 2011, at 2:37 AM, Felix Radensky wrote: On P1022DS both ethernet controllers are connected to RGMII PHYs accessible via MDIO bus. Remove fixed-link property from ethernet nodes as they only required when fixed link PHYs without MDIO bus are used. Signed-off-by: Felix Radensky