RE: [PATCH 3/3] eSDHC: fix incorrect default value of the capabilities register on P4080

2011-07-17 Thread Zang Roy-R61911
fix incorrect default value of the > capabilities register on P4080 > > On Tue, Jul 05, 2011 at 12:19:03PM +0800, Roy Zang wrote: > > P4080 eSDHC errata 12 describes incorrect default value of the > > the host controller capabilities register. > > > > The default va

Re: [PATCH 3/3] eSDHC: fix incorrect default value of the capabilities register on P4080

2011-07-05 Thread Anton Vorontsov
On Tue, Jul 05, 2011 at 12:19:03PM +0800, Roy Zang wrote: > P4080 eSDHC errata 12 describes incorrect default value of the > the host controller capabilities register. > > The default value of the VS18 and VS30 fields in the host controller > capabilities register (HOSTCAPBLT) are incorrect. The d

[PATCH 3/3] eSDHC: fix incorrect default value of the capabilities register on P4080

2011-07-04 Thread Roy Zang
P4080 eSDHC errata 12 describes incorrect default value of the the host controller capabilities register. The default value of the VS18 and VS30 fields in the host controller capabilities register (HOSTCAPBLT) are incorrect. The default of these bits should be zero instead of one in the eSDHC logi