Hi,
> No, in a correctly configured gPTP network, all of the nodes have the same
> settings.
Hmm, I don't agree ... The purpose of Signaling messages was to
communicate/request rates that are needed by the slave/requester device and
each slave device can have different "needs". What is more, as
On Mon, Jun 14, 2021 at 12:03:45PM +, Miklas, Marcin via Linuxptp-devel
wrote:
> gPTP requires that PTP_TIMESCALE flag is set in messages. I noticed that
> PDelayReq, PDelayResp, PDelayRespFollowUp, Sync, FollowUp and Signaling all
> have
> that flag set to 0. One of the bridges just ignores