Re: [Linuxptp-users] Empty Sync Message using EVB-LAN7430 and one-step-sync

2020-07-02 Thread Timo Korthals
First of all: The issue is resolved. The EVB-LAN7430 seems to work just fine and it was me who performed a bad wireshark dump. The EVB-LAN7430 is the grandmaster (GM) and I also dumped the packages with this device. Since timestamping for one-step-sync happens in hardware, it is most probable

[Linuxptp-users] Empty Sync Message using EVB-LAN7430 and one-step-sync

2020-06-29 Thread Timo Korthals
Dear linuxptp users, I'd like to set up the EVB-LAN7430 [1] as a PTP grandmaster, which serves the system's time to some embedded devices with one-step-sync. I've noticed that the time in the embedded devices will be set accordingly, but with a random offset of 0.5 to 30 seconds (therefore, no U

Re: [Linuxptp-users] Empty Sync Message using EVB-LAN7430 and one-step-sync

2020-06-29 Thread Timo Korthals
I've attached the wireshark dump to this message. On Tuesday, June 30, 2020 04:32 CEST, "Timo Korthals" wrote: > Dear linuxptp users, > > I'd like to set up the EVB-LAN7430 [1] as a PTP grandmaster, which serves the > system's time to some embedded devices with one-step-sync. > I've noticed t