On Fri, Dec 05, 2003 at 10:22:56AM -1000, Warren Togami wrote:
> IMHO Videl does not need the extra disk capacity and the money
> for 2x160GB disks would be much better spent in 250GB+ sized
> disks for the mirror array. We need to reach around the $1,100
> mark if we will be able to buy 1TB of sto
On Fri, 2003-12-05 at 09:27, Matthew John Darnell wrote:
> Vince,
>
> Is their a particular drive you have in mind, or just any 160GB disk.
>
> -Matt
If this is to make Videl's system drive 2x160GB RAID1, then the
identical brand and model would be ideal.
IMHO Videl does not need the extra disk
On Fri, Dec 05, 2003 at 09:27:26AM -1000, Matthew John Darnell wrote:
> Is their a particular drive you have in mind, or just any 160GB disk.
I am taking this off-list to expedite things.
-Vince
Vince,
Is their a particular drive you have in mind, or just any 160GB disk.
-Matt
- Original Message -
From: "Vince Hoang" <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Thursday, December 04, 2003 12:49 PM
Subject: Re: [luau] videl.ics.hawaii.edu disk fail
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1
Vince Hoang wrote:
| 3ware controller would be ideal if we stuck with an ATA solution.
|
| The others are not really hardware RAID providers at all.
I guess that means the $20 figure jumps up to >$60 to do that. Also,
the card looks alot bigger and
On Thu, Dec 04, 2003 at 11:45:48AM -1000, Warren Togami wrote:
> R.Scott Belford wrote:
> >With time, though, enough money will be gathered to buy
> >a matching larger drive ($177), and hopefully more. When
> >that time comes we can move to faster drives as Vince has
> >suggested. The 160gb drive h
On Thu, Dec 04, 2003 at 10:32:54AM -1000, Thomas Ryan Gordon Sr wrote:
> Does videl have an available PCI slot? If we still got the
> low-end 60G (and it still fits) and spent $20 on a ATA RAID
> controller we could stop doing the software RAID thing
> and improve performance and reduce CPU usage.
[luau] videl.ics.hawaii.edu disk failure - Your Help Needed
> Brian Chee wrote:
>
> > Beware, I've just been burned by the Promise ATA/133 RAID
controller...it
> > will only rebuild the array if you give a new drive of identical
> > geometryunlike SCSI based
R.Scott Belford wrote:
This was my motivation in buying a larger drive. If installed now, it
solves redundancy issues but is not a true permanent solution. Software
raid with different sized drives has a few more steps, I guess, with
formatting, but this is not a big deal, is it? With time
Brian Chee wrote:
Beware, I've just been burned by the Promise ATA/133 RAID controller...it
will only rebuild the array if you give a new drive of identical
geometryunlike SCSI based raid which only need a similar or larger sized
drive.
I'm exploring 3ware's offerings and am enthusiastic ab
On Wednesday, December 3, 2003, at 09:17 AM, Vince Hoang wrote:
On Tue, Dec 02, 2003 at 08:31:44PM -1000, R. Scott Belford wrote:
Is priority one to replace the failed drive for this array? If
so, what size? I can order it tomorrow. I am assuming that it
needs to match the other 120gb drive I d
t: Thursday, December 04, 2003 10:32 AM
Subject: Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed
> -BEGIN PGP SIGNED MESSAGE-
> Hash: SHA1
>
> R.Scott Belford wrote:
>
> | I am saddened
>
> Don't be sad, I was just learning that the RAID is in-
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1
R.Scott Belford wrote:
| I am saddened
Don't be sad, I was just learning that the RAID is in-fact
software-based and all 160 gigs will be usable. The more hard-drives,
the merrier.
But back to the tech stuff. I just had a thought about videl but
On Thursday, December 4, 2003, at 01:16 AM, Warren Togami wrote:
160GB 7200rpm 8MB cache
60GB 7200rpm 2MB cache
Unfortunately this means that Videl will still be limited in
performance
to the 2MB cache of the smaller disk. While the 60GB system drive
portion can be made redundant across bot
On Wed, 2003-12-03 at 23:38, Thomas Ryan Gordon Sr wrote:
> >> We should get another 60GB drive to mirror the other 60GB drive.
> >> Preferably of the same model so they both run with similar speed and
> >> access times. The exact model is $99 at local CompUSA, but I'm looking
> >> for better deal
R.Scott Belford wrote:
On Wednesday, December 3, 2003, at 11:48 AM, Warren Togami wrote:
We should get another 60GB drive to mirror the other 60GB drive.
Preferably of the same model so they both run with similar speed and
access times. The exact model is $99 at local CompUSA, but I'm lookin
On Wednesday, December 3, 2003, at 11:48 AM, Warren Togami wrote:
We should get another 60GB drive to mirror the other 60GB drive.
Preferably of the same model so they both run with similar speed and
access times. The exact model is $99 at local CompUSA, but I'm looking
for better deals elsewh
>
> On Wednesday, December 3, 2003, at 07:45 AM, Warren Togami wrote:
>
>> I really want to launch server 3 with more than 240GB storage... but
>> are
>> you sure you are doing your math right? 120GB 2x mirrored is not
>> 240GB... anyhow we'll figure it out.
>>
>
> My sentence may have been mislea
On Tue, Dec 02, 2003 at 08:31:44PM -1000, R. Scott Belford wrote:
> Is priority one to replace the failed drive for this array? If
> so, what size? I can order it tomorrow. I am assuming that it
> needs to match the other 120gb drive I donated last year.
One of the root disks died. I believe both
On Wednesday, December 3, 2003, at 07:45 AM, Warren Togami wrote:
I really want to launch server 3 with more than 240GB storage... but
are
you sure you are doing your math right? 120GB 2x mirrored is not
240GB... anyhow we'll figure it out.
My sentence may have been misleading. What I mean
On Tue, 2003-12-02 at 20:31, R. Scott Belford wrote:
>
> On Tuesday, December 2, 2003, at 07:44 PM, Warren Togami wrote:
>
> snip ---
>
> > Apparently one of the disks in the RAID1 array of videl.ics.hawaii.edu
> > failed during November. I am hoping for donations to help pay for the
> > replac
Warren- I'll donate the lunch money intended for celebrating your
finishing your finals to help this crisis. I am only interested in
desktop projects which are closely tied to local causes. My own limited
funds will have to be saved for those activities.
Don't we wish that Chris Hemeter wer
On Tuesday, December 2, 2003, at 07:44 PM, Warren Togami wrote:
snip ---
Apparently one of the disks in the RAID1 array of videl.ics.hawaii.edu
failed during November. I am hoping for donations to help pay for the
replacement disk and other upcoming server upgrades that are needed.
Is prio
Nov 9 13:11:23 videl kernel: hdc: dma_intr: status=0x51 { DriveReady
SeekComplete Error }
Nov 9 13:11:23 videl kernel: hdc: dma_intr: error=0x40 {
UncorrectableError }, LBAsect=53035364, sector=53035232
Nov 9 13:11:23 videl kernel: end_request: I/O error, dev 16:01 (hdc),
sector 53035232
Nov 9
24 matches