Well at the end i have test the original board with ampere meter and i have
see some current pic until 13/16A when i load the motor at low rpm.
Over the web info about this lathe or this motor power and with math i have
set the KBMG to 5A max, RCL/FCL set to default 150% so i wait for max ~7.5A
Hi
Thanks for your reply, at middle to high rpm ~800/3000 the KBMG have a good
torque. This is only for low rpm i have try many things with IR and Resp
max etc but as you suggest i can try another attempt ! I haven't change the
default RCL FCL settings.
Yes setup is speed mode, regen to stop,
That KBMG can easily handle that 1hp motor, it's designed for up to 2hp. On
a brushed DC motor the torque is directly related to current. If you have a
problem with low end torque you probably did not setup the IR comp and CL
pots correctly. That drive needs to be setup in speed mode as you are