AW: Series branches PI model equivalent

2017-07-06 Thread Leon Thurner
That is not correct, the impedance has to be in series, not in parallel. The admittance are indeed in parallel, but remember that a parallel connection of admittances is calculated as Y = Y1 + Y2. The equivalents are then simply: Z = Z1 + Z2 (series impedances) Y = Ysh1 + Ysh2 (parallel admi

Re: DCOPF not converge

2017-07-06 Thread prem panigrahi
Dear Ray Sir In my case i have 4 Island and remove the buses of 3 Island having no generation and the Island 1 have a reference bus. In generation side dispatched load is less than the capacity due to which there is a mismatch in load and generation. Is it a natural case or I can

Re: CPF Callback Functions

2017-07-06 Thread Ray Zimmerman
You can just copy cpf_default_callback.m (or any of the other cpf__cb.m callback functions), rename it, and replace the contents with your own functionality. Ray > On Jul 5, 2017, at 2:25 PM, Majid Mehdizadeh wrote: > > I mean the function. > > On Jul 5, 2017 10:54 PM, "Majid Mehdizadeh

Re: To make changes in runpf.m

2017-07-06 Thread Ray Zimmerman
It is not clear what you are trying to accomplish, but MATPOWER code is just like any other Matlab code. You can duplicate and rename runpf.m and modify it to your heart’s content. However, multiplying an entire bus or branch matrix by 2 is certainly not a valid thing to do. For one thing the bu

Re: DCOPF not converge

2017-07-06 Thread Ray Zimmerman
I’m not sure I understand your question. But you will need to run a power flow or OPF on island 1 in order to have a valid power flow solution with matching load and generation. Ray > On Jul 6, 2017, at 3:39 AM, prem panigrahi wrote: > > Dear Ray Sir > In my case i have 4 Is

Re: Non-Convergence of Load Flow in Reconfiguration / Restoration Situations (via Optimization)

2017-07-06 Thread Andrey Vieira
Oh, I got it. Mr. Todorovski, thank you so much. De: bounce-121640945-77188...@list.cornell.edu em nome de Mirko Todorovski Enviado: quarta-feira, 5 de julho de 2017 22:04 Para: MATPOWER discussion forum Assunto: Re: Non-Convergence of Load Flow in Reconfigur