be
just an example to make clear for what I am searching.
Thank you for your help.
Christian
> Am 06.11.2014 um 09:16 schrieb Christian Orberger
> :
>
> Hi Ray,
>
> thank you for your answer. I will think about that and if I don't get further
> I will write an
ators.
Ray
On Nov 5, 2014, at 6:20 AM, Christian Orberger
wrote:Hi Ray,
thank your for this hint.
It weren't these variables, but the variables of the dummy generators, which
are added in "toggle_dcline" from line 153. There I would like to define
constraints of the variabl
, 4 Nov 2014 11:19:47 -0500
To: matpowe...@list.cornell.edu
Hi Christian,
See Table B-5 in the User’s Manual. I think the QMINF, QMAXF, QMINT, QMAXT are
the parameters you are looking for, right?
Ray
On Nov 4, 2014, at 3:54 AM, Christian Orberger
wrote:Hi Uriel,
thank you for your answer.
I saw
30 -0600
To: matpowe...@list.cornell.edu
Hi Christian,
As far as i know, matpower does not include FACTS devices (such HVDC), you will
have to code it.
Best regards,
Uriel
El 03/11/2014, a las 6:51, Christian Orberger
escribió:Hello,
I want to extend the P-Q constraints of an HVDC Converter in the
Hello,
I want to extend the P-Q constraints of an HVDC Converter in the OPF in
Matpower. My question is, if there already are any constraints regarding these
converters in the OPF and if yes, where I can find them in the programm? Or do
I have to implement completely new constraints?
Thank you