The targetcasedata is simply the basecasedata with a different load / 
generation pattern. As the continuation parameter lambda is varied from 0 to 1, 
the system load/generations vary from those of basecasedata to those of 
targetcasedata. See the example at the end of the CPF chapter in the manual 
where the target case is simply the base case with generation and load 
increased by a factor of 2.5.

     Ray


> On Aug 17, 2017, at 8:30 AM, hushuai1...@foxmail.com wrote:
> 
> I want to ask a question about the CPF program of matpower 6.0.
> <Catch(08-17-20-30-05).jpg>
> As show in picture above, 
> my doubt :
>  What is different between basecasedata and tragetcasedata? 
>  What is the meaning of tragetcasedata?
> I still cannot understand after i read the examle in manual, thanks for give 
> me some pointing.
> Have a nice day!

Reply via email to