Dear Bela,
As far as I know the *UCTE_2002_Summer.m *model* *was made just for DC
analysis.
if you see in the model, in the branch data part, the components of the
line r and b are equal to zero.
I think, that is the reason why the model did not converge in AC analysis.
You have to complete
Dear Álvaro,
Thank you for sharing this information. I will let you know when we will
have more progress with this model.
Thanks,
Bela
On 10/4/2012 11:39 AM, Álvaro Jaramillo Duque wrote:
Dear Bela,
As far as I know the *UCTE_2002_Summer.m *model* *was made just for DC
analysis.
if you
Dear Bela:
Running MINOPF on the system, it seems that both active and reactive
balances are hard to fulfill in bus 706.
Carlos.
Bela Genge wrote:
Dear all,
I am having some problems running an AC power flow with the attached
case system. This is an approximate EU Power Grid model that