Re: [Meep-discuss] Time average of intensity obtained from get-field-point

2012-09-11 Thread pankaj kumar sahoo
Dear Prof Johnson Thanks for your reply. As per your suggestion i changed my source to Gaussian-src. But i am not getting the result i need. I want to incident picosecond ultrashort pulses from above the slab on to its surface normally (in the Z-direction) to have third order nonlinearity. For

Re: [Meep-discuss] Time average of intensity obtained from get-field-point

2012-09-03 Thread Steven G. Johnson
On Sep 2, 2012, at 3:59 AM, pankaj kumar sahoo wrote: Thanks for your reply. I understood that i have to take time average over half-a-period. But the time-averaged value obtained is different for different periods. For example value of average intensity is different for periods 290-291

[Meep-discuss] Time average of intensity obtained from get-field-point

2012-08-25 Thread pankaj kumar sahoo
Dear meep users When using get-field-point and passing Sx to find the intensity due to the Ex polarized light,i got Sx at a single point at different time unit. I want to calculate the time average of Sx at that single point. I used run-until 300 time unit.I dont know how to take the time