Dear Prof Johnson
Thanks for your reply. As per your suggestion i changed my source to
Gaussian-src. But i am not getting the result i need.
I want to incident picosecond ultrashort pulses from above the slab on to
its surface normally (in the Z-direction) to have third order nonlinearity.
For
On Sep 2, 2012, at 3:59 AM, pankaj kumar sahoo wrote:
Thanks for your reply. I understood that i have to take time average over
half-a-period. But the time-averaged value obtained is different for
different periods. For example value of average intensity is different for
periods 290-291
Dear meep users
When using get-field-point and passing Sx to find the intensity due
to the Ex polarized light,i got Sx at a single point at different time
unit.
I want to calculate the time average of Sx at that single point. I
used run-until 300 time unit.I dont know how to take the time
3 matches