Re: [MBZ] Commercial freezer

2023-07-22 Thread Kaleb Striplin via Mercedes
You could be right. I just looked at it and from what I can see up in the fan the evaporator coils are completely iced over. It has a mechanical time clock defrost timer. I just advanced it to a defrost cycle and the compressor kicked off. I will see if it completes a defrost cycle and/or if the

Re: [MBZ] Commercial freezer

2023-07-22 Thread Allan Streib via Mercedes
It should go through a defrost cycle periodically. Perhaps the heating element for that is bad, or a relay or timer... ? On Sat, Jul 22, 2023, at 09:08, Kaleb Striplin via Mercedes wrote: > Anyone know anything about commercial freezers? Wife has a true at the > bakery that the compressor is a b

[MBZ] Commercial freezer

2023-07-22 Thread Kaleb Striplin via Mercedes
Anyone know anything about commercial freezers? Wife has a true at the bakery that the compressor is a big old heavy duty thing built like a 240D. When we had it at the house it seemed to run non stop. Long story short the thermostat was bad. Replaced that and it seemed to work for a while but t

Re: [MBZ] commercial freezer

2022-06-25 Thread Kaleb Striplin via Mercedes
This was one built in 99 and it’s pretty simple. Sent from my iPhone > On Jun 25, 2022, at 7:07 PM, Allan Streib via Mercedes > wrote: > > I have to admit I'm a bit surprised. I haven't worked with any restaurant > equipment since the late 1980s but what I remember of it is that it was *not

Re: [MBZ] commercial freezer

2022-06-25 Thread Allan Streib via Mercedes
I have to admit I'm a bit surprised. I haven't worked with any restaurant equipment since the late 1980s but what I remember of it is that it was *not* sophisticated. Reliability was paramount; no restaurant would be happy about losing a freezer full of food. Therefore things were simple and ove

Re: [MBZ] commercial freezer

2022-06-25 Thread Kaleb Striplin via Mercedes
Let it run for a while and both fans are running. The only thing I can think of as to why the one fan was not running is if you are not careful the wiring in the area can drop down and get caught in the fan. Maybe that is what happened. Working on putting the cover back on which is a bear. Sen

Re: [MBZ] commercial freezer

2022-06-25 Thread Kaleb Striplin via Mercedes
I have the freezer running now and the fans reinstalled. That temp switch it mounted right on the evaporator so I am assuming once it cools down enough then fans will kick on. We shall see. Sent from my iPhone > On Jun 25, 2022, at 4:59 PM, dan penoff.com via Mercedes > wrote: > > As a lad

Re: [MBZ] commercial freezer

2022-06-25 Thread dan penoff.com via Mercedes
As a ladder diagram guy like Jim, I’m in total agreement that both fans have to run at the same time or there is a wiring or connection issue, no question about it. -D > On Jun 25, 2022, at 2:57 PM, Kaleb Striplin via Mercedes > wrote: > > Yea, I do not take any credit for their schematic.

Re: [MBZ] commercial freezer

2022-06-25 Thread Kaleb Striplin via Mercedes
Yea, I do not take any credit for their schematic. Since the fans are wired together I am not really sure why one would run but the other would not yet both powered up fine with power applied directly.  I am going to reinstall the fans and let the unit run for a while.  I am assuming the evapor

Re: [MBZ] commercial freezer

2022-06-25 Thread Jim Cathey via Mercedes
Not impressed with your schematic. The relay (? defrost timer?) is drawn in a somewhat non-standard, and certainly confusing manner. Also, the skinny terminal on the compressor outlet is supposed to be the 'hot' side, usually black (versus white). The evap fans have to run together. If they d

Re: [MBZ] commercial freezer

2022-06-25 Thread Kaleb Striplin via Mercedes
My mistake it has 3 wires a black, white, and brown Sent from my iPhone > On Jun 25, 2022, at 4:36 PM, Kaleb Striplin wrote: > >  > The new thermostat and evaporator fan arrived and I replaced the thermostat. > Compressor kicks on fine. Before all this is had one of the 2 evaporator > fa

[MBZ] commercial freezer

2022-06-25 Thread Kaleb Striplin via Mercedes
The new thermostat and evaporator fan arrived and I replaced the thermostat.  Compressor kicks on fine.  Before all this is had  one of the 2 evaporator fans not running.  I ordered a replacement but when the unit kicked on, neither one of them were running.  They should run when the 2 door c

Re: [MBZ] Commercial freezer

2022-06-19 Thread Kaleb Striplin via Mercedes
wall by the cord. >> I'm saying that in 23 years of use, someone did several times. It failed >> on you. Those old freezers are like the 240D of freezers. >>> >>> >>> Rick >>> >>> From: mercedes@okiebenz.com >>> Sent: June 19,

Re: [MBZ] Commercial freezer

2022-06-19 Thread Kaleb Striplin via Mercedes
m not saying you yanked it out of the wall by the cord. >> I'm saying that in 23 years of use, someone did several times. It failed >> on you. Those old freezers are like the 240D of freezers. >>> >>> >>> Rick >>> >>> From: mercedes

Re: [MBZ] Commercial freezer

2022-06-19 Thread G Mann via Mercedes
like the 240D of freezers. > > > > > > Rick > > > > From: mercedes@okiebenz.com > > Sent: June 19, 2022 12:10 PM > > To: mercedes@okiebenz.com > > Reply-to: mercedes@okiebenz.com > > Cc: ka...@striplin.net > > Subject: Re: [MBZ] Co

Re: [MBZ] Commercial freezer

2022-06-19 Thread Allan Streib via Mercedes
ut of the wall by the cord. > > I'm saying that in 23 years of use, someone did several times. It failed > > on you. Those old freezers are like the 240D of freezers. > > > > > > Rick > > > > From: mercedes@okiebenz.com > > Sent: June 19, 20

Re: [MBZ] Commercial freezer

2022-06-19 Thread Rick Knoble via Mercedes
PM To: mercedes@okiebenz.com Reply-to: mercedes@okiebenz.com Cc: ka...@striplin.net Subject: Re: [MBZ] Commercial freezer Yep, been plugged in for days Sent from my iPhone > On Jun 19, 2022, at 11:21 AM, Allan Streib via Mercedes > wrote: > > Some of these have a delay so that they don&#

Re: [MBZ] Commercial freezer

2022-06-19 Thread Kaleb Striplin via Mercedes
Yep, been plugged in for days Sent from my iPhone > On Jun 19, 2022, at 11:21 AM, Allan Streib via Mercedes > wrote: > > Some of these have a delay so that they don't start immediately. E.g. if > there is a power failure, often the power will come back on for a few > seconds, then off, rep

Re: [MBZ] Commercial freezer

2022-06-19 Thread Allan Streib via Mercedes
Some of these have a delay so that they don't start immediately. E.g. if there is a power failure, often the power will come back on for a few seconds, then off, repeat, as it is being restored. Have you tried plugging it in and waiting at least 10 min or so? On Sat, Jun 18, 2022, at 9:10 PM, K

Re: [MBZ] Commercial freezer

2022-06-18 Thread Kaleb Striplin via Mercedes
It’s possible but there appears to be no power at all. I need to get my meter out and do some probing. Not even the interior light comes on. Sent from my iPhone > On Jun 18, 2022, at 10:53 PM, G Mann via Mercedes > wrote: > > From the diagram, bottom 1/3, there is a temperature control switc

Re: [MBZ] Commercial freezer

2022-06-18 Thread G Mann via Mercedes
>From the diagram, bottom 1/3, there is a temperature control switch, right hand side of the diagram. I would suspect it is now failing to close the circuit to the compressor. In fact, I suspect it has been sub-par for some time which is why it was "running continuously". Many years ago, a refrige

[MBZ] Commercial freezer

2022-06-18 Thread Kaleb Striplin via Mercedes
The wife has a large 2 door commercial freezer in the garage that she uses for her business.  The thing has a massive compressor and uses a ton of electricity.  Anyway, a few weeks ago we were going to be out of town for a week and it was empty, so I unplugged it so it would not be running.  Be